USER GUIDE

PRECAUTIONS

  • Do not place any corrosive or flammable materials inside the cabinet
  • Do not store food or medicine in this cabinet.
  • This product is for indoor use only.

OPTIMAL RELATIVE HUMIDITY (RH) LEVELS

RH Level

Recommended items

55%-60%

Books, Paintings, Antique Documents, Paper (Fax, Copy, Print), Cigars etc.

40%-55%

Camcorders, camera, lenses, telescopes, microscopes, endoscopes, compact discs, film negatives, film, transparency/slides, microfilm, disk drives, audio and video tapes, Musical instruments, leather products etc.

30%-40%

Metal and metal powder products, electrical equipment, semiconductors, capacitors, printed circuit boards, IC, batteries and other electronics equipment, precision measuring tools, spectrometers, etc.

Below 30%

Pharmaceutical raw materials, spices, powder coating, adhesives, seeds, pollen, dry flour, dry flowers, etc

WHEN TO BRING YOUR CABINET FOR SERVICING?

  • There is no reading on hygrometer (for all models except for I-Cabi Series).
  • There is blinking light or no red light on dehumidifier.
  • The reading on hygrometer is high despite having power.
  • The reading on hygrometer is “8888”.
  • The reading on hygrometer is stagnant despite changing the settings.

HOW TO REMOVE DEHUMIDIFIER

Remove screws from inside the cabinet, remove the cable pin connecting the hygrometer.
Dismount dehumidifier from the back of the cabinet.

Remove Dehumidifier by Digi-Cabi

Ways to Remove Dehumidifier by Digi-Cabi